The FireShield E240 automatic fireproof curtain . The innovative option best to divide the room into insulated compartments in case of fire and to prevent the spread of smoke, carbon monoxide, and fire. The instant isolation of the room will make it possible to successfully evacuate people, reduce possible damage, and eliminate the hot spot. The alarm triggered, a Gravigen drive system automatically lowers the curtain due to the gravity of the lower bar. The curtain is lifted by an electric motor. In case of power failures, a stand-alone battery allows the system to remain in operation for 72 hours.
The curtain lowers at a rate of 0.15–0.20 m/s and can be adjusted individually. At the customer request, a door loophole can be added.

Fire safety level:
EI240, with water spraying at a flow rate of 7.3 l/m2/min. per/meter run.

IMFIRE E240

DIMENSIONS
Standard version:
Maximum width ……………………….. 7m
Maximum depth of lowering: …… 6 m
Case (depth x height): .. 200 х 220 mm
Premium version:
Maximum width: …………….…. 30 m
Maximum depth of lowering: …. 14 m
Case (depth x height): .. 245 х 310 mm
LEAF
Material: …………….…. Firetex1100
Fabric weight: ………………. 660 g/m2
Weight with coating: …..….. 680 g/m2
Material thickness: ………… 0.63 mm

Curtain canvas: single-layer. The leaf fabric is certified as non-flammable and non-toxic.
CASE
Made of 1.5 mm galvanized sheet steel. To make the case leak-proof, as well as to take the tube motor’s torque, they plug it with covers from both ends.
The case size depends on the dimensions of the opening to cover and the version of the system.
Color: RAL or galvanized steel.
GUIDES
Designed to control fabric movement when unwinding a roll. Made of sheet steel. The thickness of the base profile material is 2 mm, that of the casing, 1.5 mm.
The built-in rods in the FireShield EI120 Premium version ensure the necessary tightness of the system, noiseless lowering of the leaf, and resistance to high pressures.
Color: RAL or galvanized steel.
INSTALLATION
Normally, the case is mounted in the opening, to the ceiling, tightly to the wall, or to the ceiling using suspenders. The guides are normally mounted in the opening or tightly to the wall.

Privacy Settings
We use cookies to enhance your experience while using our website. If you are using our Services via a browser you can restrict, block or remove cookies through your web browser settings. We also use content and scripts from third parties that may use tracking technologies. You can selectively provide your consent below to allow such third party embeds. For complete information about the cookies we use, data we collect and how we process them, please check our Privacy Policy
Youtube
Consent to display content from Youtube
Vimeo
Consent to display content from Vimeo
Google Maps
Consent to display content from Google
Spotify
Consent to display content from Spotify
Sound Cloud
Consent to display content from Sound

PERDE GRUBU

YANGIN PERDELERI
  1. Yangın Perdesi
  2. Yatay Yangın Perdesi
  3. Akerdeon Yangın Perdesi
DUMAN PERDELERI
  1. Duman Perdesi
  2. Statik Duman Perdesi

KEPENK GRUBU

YANGIN DAYANIMLI KEPENKLER
  1. Yangına Dayanıklı Kayar Kepenkler
  2. Yangına Dayanıklı Rulo Kepenkler
  3. Yangına Dayanıklı Seksiyonel Kepenkler
  4. Yangına Dayanıklı Kanatlı Kepenkler

DUMAN TAHLIYE GRUBU

OTOMATİK DUMAN TAHLİYELER