Fire Curtain EI60

EI60

Protects buildings from fire for a specified period of time. Can be produced as EI type. According to the type Fire curtains can be designed to provide flame, smoke, flammable gas proofing, radiation cut-off and insulation.

The insulation degree is high due to using a special material with refractory qualities which can restrain the flame over a long time period, thereby protecting people and material values against fire and smoke.

Fire safety level

Provides high temperature resistance for a long time thanks to its special design. According to the EN standard, fire resistance of 60 minutes is provided at a temperature of 1100-1200 degrees. Thus, it provides ease of movement and fire protection. Its most important task is to reflect the 1200 degree heat on one side as 140 degrees on the other side. Integrates into an existing fire detection system. Automatic Fire curtains are activated automatically by a signal received in case of danger. Prevents fire from moving from one area to another. Fire curtains operate on the principle of free-fall method (Gravigen System). Can be produced horizontally and vertically.

In case of power failure, it has its own battery that provides 72 hours of power.

What are the areas of use?

Hospitals, hotels, administrative buildings, educational institutions, shopping centers, military institutions, ships, subways, warehouses, factories, municipalities, residential buildings, conference rooms, parking lots, industrial facilities, atriums, museums, elevator facades, as well as fire departments compartments, counterceilings, entrances to lobbies, entrances to industrial kitchens, in front of switchboards, public places.

Fire Resistance Limit

EI60

Fire Curtain Dimensions

FireType Maximum Width Maximum depth of lowering
Standart 6.5 m 6 m

Box and Side Rail Dimensions

 

Type Box Side Rail
Standart 350x380mm 150x60mm

Fabric

Fabric material: Firetex 60, 4760 g/m2

Box

Made of galvanized steel sheet with 1.5 mm thickness. The box has a lid on both sides. Box dimensions depend on the size of the opening being closed.

Guides

Side guides are designed for loaded fabric. Made from galvanized sheet steel. Main profile thickness is 2mm, housing thickness is 1.5mm.

Installation

Box: can be installed on the inside of the wall, on the surface of the wall, in the counterceiling, and on the ceiling with rod hangers.

Side guides:
can be installed on the inside of the wall, on the surface of the wall

Color

Сan be selected from the RAL chart or can be galvanized.

Note: The fabric is registered with certificates that it is not toxic and non-combustible.