Fire Curtain EW240

(EN 1634 -1 Standard and EN 13501 -2)

Protects buildings from fire for a specified period of time. Can be produced as EW type. Can be designed to provide flame, smoke, flammable gas proofing and radiation cut-off.

According to the type of fire curtains; fire protection can be designed to provide insulation, radiation (radiation) or a few together.

Design

Provides high temperature resistance for a long time thanks to its special design. According to the EN standard, fire resistance of 60, 120, 180 and 240 minutes is provided at a temperature of 1100-1200 degrees. Thus, it provides ease of movement and fire protection. Integrates into an existing fire detection system. Automatic Fire curtains are activated automatically by a signal received in case of danger. Prevents fire from moving from one area to another. Fire curtains operate on the principle of free-fall method (Gravigen System). Can be produced horizontally and vertically.

In the event of a power outage, it has its own battery, which provides 72 hours of power.

What are the Uses?

Hospitals, hotels, administrative buildings, educational institutions, shopping centers, military institutions, ships, subways, warehouses, factories, municipalities, residential buildings, conference rooms, parking lots, industrial facilities, atriums, museums, elevator facades, as well as fire departments compartments, counterceilings, entrances to lobbies, entrances to industrial kitchens, in front of switchboards, public places.

Fire Resistance Limit

EW60, EW120, EW180, EW240

Fire Curtain Dimensions

Fire Curtain Type Maximum Width Maximum Height
Fire Curtain EW240 6.5 m 6 m

Box and Side Rail Dimensions

Type Box Side Rails
Standart 350x380mm 150x60mm

Fabric

Fabric material: Firetex W240, 2760 gr/m2

Box

Made of galvanized steel sheet with 1.5 mm thickness. The box has a lid on both sides. Box dimensions depend on the size of the opening being closed.

Guides

Side guides are designed for loaded fabric. Made from galvanized sheet steel. Main profile thickness is 2mm, housing thickness is 1.5mm.

Installation

Box: can be installed on the inside of the wall, on the surface of the wall, in the counterceiling, and on the ceiling
with rod hangers.

Side guides: can be installed on the inside of the wall, on the surface of the wall

Product Color

It can be selected or galvanized from the RAL cartel.
Note: The fabric is registered with certificates that it is not toxic and non-combustible.